SmogRank / Air purifier guide
Air purifiers for smoke and PM2.5: what to buy and what size
A purifier cleans the air of one room by pulling it through a filter. What decides how well it works is how much clean air it delivers for the size of the room, and whether it runs: buy for the room, then leave it on.
Our boards and city pages show when the air outside is bad. This page is about the air inside. It keeps to what the US EPA and the studies it cites have measured, linked as we go. We name no brands.
The one number to read: CADR
Most purifiers are rated by their clean air delivery rate (CADR), measured at the highest speed. Packaging often gives three: for tobacco smoke, dust and pollen, which stand for small, medium and large particles. For PM2.5 and wildfire smoke, read the tobacco smoke CADR (EPA, Guide to Air Cleaners in the Home). The higher it is, the faster the room's air is cleaned and the bigger the room it can serve.
CADR is in cubic feet a minute (cfm). The EPA's minimum, 65 cfm for every 100 square feet under an 8-foot ceiling, passes the room's whole volume through the filter about 4.9 times an hour.
How big for your room
Multiply the room's length by its width for its floor area, and look for a smoke CADR at least as large as this chart's. Enter your own room to work it out; a ceiling over 8 feet (2.4 m) scales it up.
| Room | Smoke CADR, at least |
|---|---|
| 100 ft² (9 m²) | 65 cfm (110 m³/h) |
| 150 ft² (14 m²) | 100 cfm (165 m³/h) |
| 200 ft² (19 m²) | 130 cfm (220 m³/h) |
| 300 ft² (28 m²) | 195 cfm (330 m³/h) |
| 500 ft² (46 m²) | 325 cfm (550 m³/h) |
For an open floor plan, count the whole space the purifier serves. A space larger than any one unit can serve takes two or more. The chart is a minimum: the EPA's DIY research page quotes the Association of Home Appliance Manufacturers suggesting a CADR equal to the floor area in square feet, half again the chart's, and in heavy smoke more margin cleans the room faster.
Paid link: HEPA air purifiers on Amazon.ca (Canada store) · HEPA air purifiers on Amazon.com (United States store)
HEPA, carbon, and what to avoid
A HEPA filter is the usual way to a high CADR. HEPA (high efficiency particulate air) is defined by the US Department of Energy: it removes at least 99.97% of particles 0.3 microns across, the size that gets through most easily, and catches larger and smaller ones better still (EPA, What is a HEPA filter?).
The CADR covers particles only. For smells and gases you need an activated carbon filter, and only a large amount of carbon does much; no widely used rating exists for it. The EPA notes research hasn't shown plasma, photocatalytic oxidation or UV light removing gases well in home purifiers.
Skip ozone generators sold as air cleaners: ozone irritates the lungs, no US federal agency has approved them for occupied rooms, and at levels within health standards ozone does little to clean indoor air (EPA, Ozone Generators that are Sold as Air Cleaners). Ionizers, electrostatic precipitators, plasma units and some UV lights can give off ozone too. The California Air Resources Board keeps a list of air cleaners tested to emit little or no ozone.
Living with one
- Put it in the room you spend most time in, often a bedroom, with nothing blocking its airflow: away from curtains and furniture.
- Higher speeds and longer running clean more air. During smoke, the EPA advises running it all the time, on the highest setting you can stand.
- If noise would make you turn it off, look for a low noise rating. For scale, the EPA puts about 50 decibels at a modern refrigerator's hum.
- Change filters as the maker says. A dirty, loaded filter doesn't work well, and smoke loads one fast: check it more often while the air is bad.
- An ENERGY STAR label is about electricity use only, not how well the unit cleans.
The cheap option: a box fan with a filter
A box fan with a MERV 13 furnace filter strapped to it is a real purifier. The EPA measured several designs in a room-sized chamber filled with smoke from smouldering pine needles, and designs with a shroud and several filters removed particles better than higher-priced commercial units (EPA, Research on DIY Air Cleaners to Reduce Wildfire Smoke Indoors). The EPA recommends them for when commercial purifiers aren't available or affordable, not as a permanent replacement: each one built performs a little differently.
| Design (MERV 13 filters) | Smoke CADR | Room at the EPA's rate |
|---|---|---|
| One 1-inch filter on the fan | 111 ± 1 cfm | 170 ft² (16 m²) |
| One 1-inch filter, cardboard shroud | 156 ± 4 cfm | 240 ft² (22 m²) |
| One 4-inch filter, cardboard shroud | 248 ± 15 cfm | 380 ft² (35 m²) |
| Two 1-inch filters, cardboard shroud | 263 ± 22 cfm | 400 ft² (37 m²) |
| Four 1-inch filters in a cube (Corsi-Rosenthal box), shroud | 401 ± 31 cfm | 620 ft² (58 m²) |
Holder and others, 2022, measured by the US EPA with simulated wildfire smoke. The shroud, a piece of cardboard over the fan's corners, adds about 40% at no cost. Room size: the CADR at the EPA chart's 65 cfm per 100 ft².
Use a box fan from 2012 or later with a UL or ETL mark: newer fans have fused plugs and thermal cutoffs, and in UL's tests of five such fans every temperature stayed below the safety standard, even blocked on both sides for seven hours. Don't use an extension cord, don't leave children alone with it, and keep smoke detectors working. With dirty filters these units stopped working almost entirely, so keep spares and change one when it turns dark grey or brown or smells of smoke.
Paid link: MERV 13 filters on Amazon.ca (Canada store) · MERV 13 filters on Amazon.com (United States store)
One clean room during smoke
When smoke comes, it is easier to keep one room clean than a whole home. The EPA's steps (EPA, Create a Clean Room):
- Choose a room big enough for everyone in the home and comfortable for long stays; a bedroom with its own bathroom works well.
- Close its windows and doors, without making it hard to get out. Use an exhaust fan or range hood only briefly: it pulls in smoke from elsewhere.
- Stay cool. Set central or window air conditioning to recirculate, with any fresh-air intake closed.
- Filter it: a purifier sized for the room, running continuously on its highest setting, or a box-fan filter.
- Make no smoke inside: no smoking or vaping, frying or broiling, candles or incense, gas or wood stoves, aerosol sprays, or vacuuming without a HEPA filter. Dust with a damp cloth. When the air outside improves, even for a while, air the room out.
With central air, fit the best filter the system takes, MERV 13 or higher (a MERV 13 filter must remove at least half of the smallest particles tested), and set the fan to On rather than Auto: it filters only while it runs, and it often runs less than a quarter of the time. An HVAC technician can say what your system takes.
What a purifier won't do
- Make up for the source: keeping smoke out and making none inside come first, and filtering is a supplement.
- Remove gases on a HEPA filter alone: the CADR is for particles.
- Fix mould: that needs the damp it grows from dealt with.
- Come from a window or wall air conditioner: their filters keep the machine clean, not the room's air.
- Keep you safe if the room gets too hot or smoke still gets in: then a cooler place with filtered air comes first, with friends, at a public cleaner-air shelter or in a large air-conditioned building.
When to switch it on
Whenever the air outside is bad. Every city page here shows the last hours and days, and while a city's air is over the EPA's level for sensitive groups (35.5 µg/m³), the page opens a box with what to do and this sizing chart. The rankings show where the air is worst now. How much smoke gets inside a shut home, and how much a purifier takes out: our guide.
As an Amazon Associate, SmogRank earns from qualifying purchases.
General information, not medical advice. For decisions about your health, follow your doctor and your local air quality authority.