SmogRank / Home monitors
What a home air monitor shows: CO₂, VOCs and dust
The CO₂ number tells you how much of a room's air has been breathed already. Outdoor air held 426 ppm of CO₂ in July 2026, the latest global monthly mean NOAA has published. Researchers count what a room reads above that as breath when nothing is burning, so at 1,000 ppm, Health Canada's limit for homes averaged over a day, about 1.5% of the air in the room has been breathed out before by the people in it.
The VOC number has no such scale: it compares the room with its own last 24 hours. The dust number, PM2.5, is the one you can check against the air outside your city.
CO₂: how much of the air is breath
| CO₂ (ppm) | Above outdoors | Breathed before |
|---|---|---|
| 426 outdoors | 0 | 0% |
| 600 | 174 | 0.5% |
| 800 | 374 | 1.0% |
| 1,000 Health Canada | 574 | 1.5% |
| 1,500 | 1,074 | 2.9% |
| 2,000 | 1,574 | 4.2% |
The share of a room's air that has already been breathed out is the reading minus outdoor air (426 ppm), divided by how much CO₂ breathing adds to the air we breathe out: 37,500 ppm, the figure Vouriot and others, Indoor Air, 2021 use with this method from Rudnick and Milton (2003). Other papers use 31,500 (Banholzer and others, 2024) to 40,000 ppm (Zürcher and others, 2020), which puts the share at 1,000 ppm between 1.4% and 1.8%. The share says how well the room is aired for the people in it, not who breathed the air or whether anyone in it is ill.
What Health Canada's limit means
Health Canada recommends a long-term exposure limit of 1,000 ppm of CO₂ in homes, as a 24-hour average (Health Canada's guideline, 2021). To compare a home with it, it says to measure for at least 24 hours under normal conditions, and that repeating the measurement at different times of year gives a better estimate.
The limit rests on studies, mostly in schools and offices, that linked higher CO₂ with more respiratory and mucous membrane symptoms, headaches, tiredness and difficulty concentrating, and lower test scores. Health Canada says no causality can be determined: when a room is poorly aired, other pollutants rise with CO₂, including what people's bodies give off. It reads CO₂ as a measure of how well a home is aired, and recommends ventilation to keep it down.
In the homes those studies measured in six Canadian cities, the typical hour (each study's median) read 418 to 729 ppm, and the level only 5% of hours went over was at most 1,483 ppm. In winter the typical hour ran about 80 to 160 ppm higher. Winter studies of on-reserve First Nations homes in Ontario and Manitoba found typical hours of 1,058 to 1,139 ppm.
Reading your monitor
- Read the day, not the moment. A room's CO₂ climbs while people are in it and falls when they leave or a window opens; the limit is for the average over 24 hours.
- Put it at the height where people breathe and away from windows and other openings, as researchers place theirs, and not right beside someone's face, where it reads their breath directly.
- Flames add CO₂ too. Health Canada lists gas stoves, unvented or poorly vented heaters and furnaces and smoking, and reports peaks of up to 3,000 ppm measured in homes with a gas stove. While one is burning, the share in the table counts that CO₂ as breath and reads too high.
- The 426 ppm is an average over sites by the sea (NOAA's global trend). Outside four Ottawa schools, Health Canada's study measured a typical 419 ppm, with the highest 5% of readings over 532 ppm: a city's own outdoor air can run above the global figure at times, and then the share here reads a little high.
VOCs: compared with the room's own last day
VOCs are gases from cooking, cleaning, breathing and whatever in a room slowly gives them off. A home monitor's VOC reading isn't a measured amount of them. The sensor maker Sensirion's VOC Index, for one, runs from 1 to 500 and puts the room's average over the sensor's last 24 hours at 100.
So 100 means usual for this room, not safe, and 100 in two homes can be different air. The index also rescales itself to the last day's events, reacts to VOCs that have no smell, and can't tell one compound from another (What is Sensirion's VOC Index?). There is no health figure to hold it against: it is useful for spotting when something in the room changed, and whether airing the room brings it back down.
Some monitors show VOCs as a concentration instead, in ppb or µg/m³. Sensirion says a concentration can't be properly given from its sensors in real rooms, which is why they report an index. Read such a number the same way: as a change, not a level.
Dust: PM2.5
The dust reading is PM2.5, the same measure this site ranks cities by, so it is the one number on a home monitor you can hold against the air outside: your city's page shows it hour by hour. How close a low-cost sensor's PM2.5 is to a government monitor's, measured by us: how accurate low-cost sensors are. How much outdoor smoke a shut home lets in: smoke indoors. Bringing it down: choosing and sizing a purifier.
Paid link: PM2.5 monitors on Amazon.ca (Canada store) · PM2.5 monitors on Amazon.com (United States store)
Sources
Outdoor CO₂: NOAA Global Monitoring Laboratory, the global monthly mean (Lan, Tans and Thoning, Trends in globally-averaged CO₂; the last year's figures are preliminary). Indoor limit and Canadian homes: Health Canada, Residential Indoor Air Quality Guidelines: Carbon Dioxide. The share already breathed: the method of Rudnick and Milton (2003), with the figure for breath from Vouriot and others (Vouriot and others, Indoor Air, 2021, CC BY 4.0). VOC Index: Sensirion, What is Sensirion's VOC Index?. The arithmetic is ours; none of them reviewed this page.
As an Amazon Associate, SmogRank earns from qualifying purchases.
General information, not medical advice. For decisions about your health, follow your doctor and your local air quality authority.